The Reliadens™

Installation

For initial installations with only one sampler, select a location in the line as far "upstream" as possible for the best opportunity to make corrections early. Select a place in the process stream where there is a 9-18 inch gravity drop. In selecting the location to monitor bulk density, consider how the product is moving or being moved at that point in the process. The Reliadens is precise and responsive. The system re-zeroes before the beginning of each cycle and samples exactly the same way each time. However, major fluctuations in flow rate can impact the readings of the very sensitive and accurate Reliadens. Typical plant vibrations and noises are effectively handled with the design of the system and algorithm.

Be aware that efforts to control bulk density mid-stream with only a single Reliadens at a particular segment in the process, such as controlling a dryer, often are extra challenging unless the bulk density is under control prior to the dryer. Such exercises may result in trying to correct bulk density with dryer control manipulation when the source of the problem is actually further upstream in the process such as the extruder or expander.

Users have seen dramatic improvements in product consistency by installing a Reliadens sampler module even ahead of the extruders to monitor the blends flowing into the extruder.

 



Home  |  About Us  |  Products  |  Common Questions  |  Tech Support  |  Feedback  |  Site Map  |  Contact  |  Search

Copyright © 2008 III Sigma. All Rights Reserved.